Measurement with Both Eyes Open
The measurement with both eyes open creates optimum condition for achieving more precise measurement. Thus, there would be less Instrumental Myopia.
Easy Measurement with the Open View Window
The Open View Window provides no distraction of the view and less stress for the patient during the measurement. It facilitates the measurement process easy and quick for the infant/children. The measurement process is smoothly done since you can observe the condition of a patient directly.
The Open View Window is easy to measure a patient with glasses and contact lens as well as a patient with IOL.
Any Target
Unlike regular refractometer, any object you can choose for the target at any distance.
Indication of SE (Spherical Equivalent)
The change of accommodation in SE can be confirmed.
Measurement of Near Point
By adjusting the working distance for near point, you can measure Near Vision objectively using near point card.
Data Output
Video Output/ It allows you to show the same image as the internal monitor to the external monitor (NTSC System).
RS-232C Interface/The measurement data is able to transfer to the external device such as the PC. (Option). The data can be automatically transferred to the spreadsheet using the measurement data collection software.
Color LCD Display
By using the color display, it becomes easier to see and confirm the alignment. Further-more, since the Icon is used instead of the character, it becomes easier to operate even if the person has never used the instrument.
Focus Guiding System
You can bring to the focus easily while you are looking at the arrow. When the arrow is gone, it is focused perfectly.
Auto Start
When it is focused, the instrument starts the measurement automatically without pressing any switch. Then, after the one eye is measured for the fixed times, it indicates to go to the other eye with sound and arrow. Furthermore, once both eyes are measured, it starts printing automatically.
Printer with Automatic Cutter
The printout can be taken off easily and cleanly since it cuts the printing paper automatically.
Measurement
PD/It measures the PD for Far Distance, automatically. Additionally, it measures the PD for Near Distance, automatically as well (Select from 30, 35, 40, and 45 cm). The result can be printed out as NPD.
IOL Mode/It makes easier to measure a patient with the IOL lens. When you select this mode, it shows as “IOL” on the printout.
Measurement of Small Pupil Diameter/Since it can measure the pupil diameter as small as 2.3 mm, it makes easy to measure the elderly or even a patient with the long eyelashes.